        How to extend the service life of frequency converter

        2023-05-20 11:29:23

        Under different operating conditions, there are still some unsatisfactory aspects of the frequency converter, resulting in the shortening of its service life and the corresponding increase of the installation, commissioning, daily maintenance and repair workload of its auxiliary equipment, thus causing significant direct and indirect economic losses to users. This paper analyzes the application environment, electromagnetic interference and anti-interference, power grid quality of the frequency converter, and puts forward the problems that should be paid attention to when using the frequency converter and the corresponding improvement suggestions. It is believed that this will have a significant effect on improving the service life of the frequency converter.


        1. Influence of electromagnetic interference on frequency converter


        In the modern industrial control system, the microcomputer or PLC control technology is often used. In the process of system design or transformation, we must pay attention to the interference of frequency converter to the microcomputer control board. Due to the external interference source, the general process level of the microcomputer control board designed by the user is poor, which does not conform to the EMC international standard. After the frequency converter is adopted, the conduction and radiation interference often leads to the abnormal operation of the control system. Therefore, the following necessary measures need to be taken.

        1) Good grounding. The grounding wire of the motor and other strong current control system must be reliably grounded through the grounding busbar, and the shielding ground of the microcomputer control board shall be separately grounded. For some serious interference occasions, it is recommended to connect the sensor, I / 0 interface shielding layer and the control ground of the control board.

        2) Adding EMI filter, common mode inductor and high frequency magnetic ring to the input power of the microcomputer control board can effectively suppress the conducted interference. In addition, in the case of serious radiation interference, such as GSM or PHS base station around, the computer control board can be shielded by adding metal mesh shield.

        3) Adding EMI filter to the input of the inverter can effectively suppress the conducted interference of the inverter to the power grid. Adding input AC and DC reactors can improve the power factor, reduce harmonic pollution and achieve good comprehensive effect. In some cases where the distance between the motor and the frequency converter is more than 100 m, it is necessary to add an AC output reactor at the frequency converter side to solve the leakage current protection caused by the distribution parameters of the output wire to the ground and reduce the external radiation interference. An effective method is to adopt the method of steel pipe threading or shielded cable, and connect the steel pipe shell or cable shield layer with the earth reliably. It is worth noting that when no AC output reactor is added, if the method of steel pipe threading or shielded cable is adopted, the distributed capacitance of output to ground is increased, and overcurrent is easy to occur. Of course, one or several methods are generally adopted in practical application.

        4) The analog sensor detection input and analog control signal are electrically shielded and isolated. In the design process of the control system composed of frequency converter, it is recommended not to use analog control as much as possible, especially when the control distance is greater than 1 m and installed across the control cabinet. Because the frequency converter generally has multi-stage speed setting, switching frequency input and output, which can meet the requirements. If it is not necessary to use analog control, it is recommended to use shielded cable and realize remote one-point grounding at the sensor side or converter side. If the interference is still serious, DC / DC isolation measures need to be implemented. The standard DC / DC module can be used, or the V / F conversion optical isolation can be used, and then the frequency setting input method can be used.


        2. Impact of working environment


        In the practical application of frequency converter, in order to reduce the cost, most domestic customers install the frequency converter directly on the industrial site except a few special machine rooms. Generally, there are dust, high temperature and high humidity problems in the work site, as well as metal dust and corrosive gas in the aluminum industry. Therefore, corresponding countermeasures must be made according to the site conditions.

        1) The frequency converter shall be installed inside the control cabinet.

        2) It is better to install the frequency converter in the middle of the control cabinet; the frequency converter should be installed vertically, and avoid installing large components that may block the exhaust and inlet air.

        3) The minimum distance between the upper and lower edge of the frequency converter and the top and bottom of the control cabinet, or the partition board, or the large components that must be installed, shall be greater than 300 mm.

        4) If a special user needs to remove the keyboard in use, the keyboard hole of the converter panel must be sealed with tape or replaced with a fake panel to prevent a large amount of dust from entering the converter interior.

        5) When the frequency converter is used in the place with multi dust, especially in the place with multi metal dust and floccules, the overall requirements are that the control cabinet shall be sealed as a whole, and the air inlet and outlet shall be specially designed for ventilation; the top of the control cabinet shall be equipped with a protective net and a protective top cover air outlet; the bottom of the control cabinet shall be equipped with a base plate, an air inlet and an air inlet hole, and a dust-proof net shall be installed.

        6) Most of the internal printed boards and metal structural parts of the inverter manufacturers have not been specially treated against moisture, mildew and mildew. If the inverter is in a bad working environment for a long time, the metal structural parts are prone to rust. Under the condition of high temperature operation, the conductive copper bar will be more severely corroded. For the small copper conductor on the microcomputer control board and the driving power board, corrosion will cause damage. Therefore, for the application in humid and corrosive gas containing occasions, there must be basic requirements for the internal design of the frequency converter used, for example, the printed circuit board must be treated with three anti paint spraying, and the structural parts must be treated with nickel plating and chromium plating. In addition, other active, effective and reasonable measures should be taken to prevent moisture and corrosion.


        3. Influence of power grid quality on frequency converter


        In the impact load such as electric welding machine, electric arc furnace, rolling mill and other occasions, the voltage often flickers; in a workshop, there are multiple frequency converters and other capacitive rectifier loads in operation, the harmonic generated by them has a very serious pollution to the quality of the power grid, and also has a considerable destructive effect on the equipment itself, light is not able to continue normal operation, heavy is the damage to the input circuit of the equipment. The following measures can be taken.

        1) It is suggested that the user should add the static reactive compensation device to improve the power factor and quality of the power grid.

        2) In the workshop where the frequency converter is concentrated, it is suggested to adopt centralized rectification and DC common bus power supply mode. 12 pulse rectification mode is recommended. It has the advantages of small harmonic and energy saving, especially suitable for frequent starting and braking. The motor is in the situation of both electric operation and power generation operation.

        3) The input side of the converter is equipped with a passive LC filter, which can reduce the input harmonic and improve the power factor.

        4) The input side of the converter is equipped with active PFC device, which has the best effect but high cost.


        4. conclusion:


        Starting from the problems in the practical application system of frequency converter, and from the interference of external factors, use environment, power grid quality and other aspects, this paper puts forward the influence of adverse factors on the frequency converter in practical application, and then summarizes some solutions to the problems and suggestions for improvement, which can play a good role in prolonging the service life of the frequency converter The application in international engineering has certain reference value.


        通用變頻器


        label

        QR code

        The public,

        Mobile station
        The public, Mobile station

        Contact

        未標(biāo)題-8.png 0755-81719517
        未標(biāo)題-10.png0755-81719530 未標(biāo)題-11.pngamb@ambition.com.cn
        未標(biāo)題-12.pngFloor 1, 5 and 6, building 7, lijincheng science and technology industrial park, gongye dong road, longhua new district, shenzhen

        Navigation

        Home          About

        Product      Case

        Solution      Service

        Job      News

        Contact          

        Copyright © Shenzhen Ambition Electronic Co., Ltd Record number:備案號(hào):粵ICP備12045920號(hào)
        主站蜘蛛池模板: 亚洲精品v欧美精品动漫精品| 亚洲国产精品久久综合网| 久久av色欲av久久蜜桃网| 97一期涩涩97片久久久久久久| 天天爽夜夜爱| AV区无码字幕中文色| 欧美一级高清片久久99| 国产AV无码专区亚洲AV漫画| 亚洲精品无播放器在线播放| 精品国产综合一区二区三区 | 国产亚洲精品综合99久久| 天天综合色一区二区三区| 日韩一区二区在线看精品| 精品国产一区二区三区av性色| 亚洲人妻一区二区精品| 亚洲精品中文字幕码专区| 成人无号精品一区二区三区| 亚洲熟妇少妇任你躁在线观看无码| 久9视频这里只有精品试看| 老太大性另类xxxⅹ| 日韩精品中文字幕人妻| 亚洲国产精品电影人久久网站| 男女激情一区二区三区| 亚洲毛片αv无线播放一区| 日韩一级伦理片一区二区| 色综合视频一区二区三区| 久久亚洲国产品一区二区| 性色欲情网站iwww| 亚洲精品不卡av在线播放 | 日本无人区一区二区三区| 国产AV老师黑色丝袜美腿| 精品黄色av一区二区三区| 两个人的视频www免费| 久久国产精品夜色| 欧美视频专区一二在线观看| 亚洲精品不卡午夜精品| 日本午夜精品一区二区三区电影| 国产毛多水多高潮高清| 在国产线视频A在线视频| 中文字幕精品亚洲四区| 午夜福利一区二区在线看|