        Key points for operation and maintenance of inverters in summer

        2023-05-20 11:38:46

        Summer is the frequent season of inverter faults. The key to ensuring long-term stable and reliable operation of the inverter is daily maintenance. In order to ensure that the inverter can operate stably in high temperature and hot summer, it is reduced due to improper maintenance or on-site operating environment. Unnecessary unplanned shutdowns are caused. During summer maintenance of the inverter, users must pay attention to the temperature of the inverter installation environment and regularly clean the dust inside the inverter to ensure the smoothness of the cooling air path. Strengthen patrol inspection to improve the surrounding environment of inverters, motors and lines. Check whether the connection terminals are tight, ensure the correct and reliable connection of each electrical return, and prevent unnecessary shutdown accidents.


        1. Confirmation of inverter installation environment


        1. Ambient temperature: Inverters generally require a minimum ambient temperature of -5 ° C and a maximum ambient temperature of 40 ° C. A large number of studies have shown that the failure rate of the inverter increases exponentially with increasing temperature, and the service life decreases exponentially with increasing temperature. If the ambient temperature increases by 10 degrees, the service life of the inverter will be halved. In summer, when the temperature is high, condensation will easily occur inside the inverter, and its insulation performance will be greatly reduced, and it may even cause a short circuit accident. The ventilation and heat dissipation of the inverter installation site should be strengthened.


        2. Summer is a rainy season, and rainwater should be prevented from entering the inverter (for example, rainwater entering the wind downwind outlet)


        3. Corrosive gas: If there is corrosive gas in the use environment, it will not only corrode the lead of the component, printed circuit board, etc., but also accelerate the aging of the plastic device and reduce the insulation performance; if there is acid or alkaline corrosion around the inverter Sexual gas, please provide targeted solutions according to the actual situation on site.


        4. Vibration and shock: When the inverter cabinet is subjected to mechanical vibration and shock, it will cause poor electrical contact. Therefore, after a period of operation, the equipment should be inspected and maintained.


        2. Matters needing attention in daily inspection


        1. Strengthen patrol inspection and arrange a special person to be responsible for the daily maintenance of the inverter;


        2. Operation data record: compile the operation record table of the inverter, regularly record the operation data of the inverter and the motor, including the inverter output frequency, output current, output voltage and other parameters, and compare and compare with reasonable data to facilitate the early detection of hidden troubles.


        3. Ensure that the ambient temperature of the inverter room is between -5 and 35 ° C. Set a special person to check whether the cooling fan on the top of the inverter cabinet is normal and whether the filter of the cabinet door is clogged. Ensure the cooling air path is unobstructed. The specific method is: put a standard thickness of A4 printing paper on the filter screen of the cabinet door, and the paper should be adsorbed on the air inlet window. In order to ensure the smoothness of the cooling air path, the filter screen should be cleaned once a week. If the site environment is dusty, the cleaning interval should be shortened.


        4. Environmental monitoring: When the temperature is high in summer, the ventilation of the frequency conversion installation site should be strengthened. Ensure that there is no excessive dust, acid, salt, corrosive and explosive gas in the surrounding air. The inverter should be protected from direct sunlight or placed near the heat source; summer is rainy season, and rainwater should be prevented from entering the inverter (such as rainwater downwind) Enter through the air outlet).


        5. Check the tightness of all electrical connections, check that there is no abnormal discharge trace in each circuit, no


        Strange smell, discoloration, cracks, damage, etc.


        6. The inverter room must be kept clean and tidy, and it should be cleaned at any time according to the actual situation on site.


        7. The ventilation and lighting of the inverter room must be good, and the ventilation and heat dissipation equipment (air conditioning, ventilation fan, etc.) can operate normally.


        three. Items that need maintenance after the inverter stops


        1. Use a vacuum cleaner with a plastic suction nozzle to thoroughly clean the inside and outside of the inverter cabinet to ensure that there is no excessive dust around the device.


        2. Check the ventilation and lighting of the inverter room, and the ventilation equipment can operate normally.


        3. Check that the connections between the cables inside the inverter should be correct and reliable.


        4. Check that all grounding in the inverter cabinet should be reliable, and the grounding point is not rusty.


        5. The nuts of the internal cable connection of the inverter should be tightened again every six months.


        6. Check the tightness of all electrical connections, and check that there is no abnormal discharge trace in each circuit, no strange smell, discoloration, cracks, damage, etc.


        7. After each maintenance of the inverter, carefully check for missing screws and wires to prevent short-circuit accidents caused by small metal objects. In particular, after making major changes to the electrical circuit, ensure that the electrical connection cable is connected correctly and reliably to prevent 'reverse power transmission' accidents.


        Frequency converter manufacturer


        label

        QR code

        The public,

        Mobile station
        The public, Mobile station

        Contact

        未標題-8.png 0755-81719517
        未標題-10.png0755-81719530 未標題-11.pngamb@ambition.com.cn
        未標題-12.pngFloor 1, 5 and 6, building 7, lijincheng science and technology industrial park, gongye dong road, longhua new district, shenzhen

        Navigation

        Home          About

        Product      Case

        Solution      Service

        Job      News

        Contact          

        Copyright © Shenzhen Ambition Electronic Co., Ltd Record number:備案號:粵ICP備12045920號
        主站蜘蛛池模板: 日韩有码中文字幕av| 国产欧美va欧美va在线| 久久99精品国产麻豆婷婷| 精品久久久久久亚洲综合网| 国产成人精品a视频| 国产中文字幕精品在线| 国产精品99一区二区三区| 久久亚洲色WWW成人欧美 | 国产福利萌白酱在线观看视频| 亚洲熟妇自偷自拍另欧美| 亚洲一区av无码少妇电影玲奈 | 中日韩黄色基地一二三区| 亚洲国产美女精品久久久| 少妇极品熟妇人妻| 成人国产一区二区精品 | 亚洲欧美日韩国产精品一区二区| 久久精品国产99久久久古代 | 人妻少妇精品系列一区二区 | 无码帝国www无码专区色综合| 国产精品无码无卡在线播放| 亚洲精品第一区二区三区| 99久久久国产精品消防器材| 人妻少妇精品系列一区二区| 亚洲色图视频一区中文字幕| 久久夜色精品国产亚av| 一道本AV免费不卡播放| 免费大片黄国产在线观看| 久久99久久精品视频| 国产精品一区二区不卡视频| 中文字幕无线码中文字幕免费| 亚洲香蕉av一区二区蜜桃| 精品国产911在线观看| 国产一区二区三区激情视频| 久久久久久久一线毛片| 又湿又紧又大又爽A视频国产| 日本一区二区精品色超碰| 成人午夜伦理在线观看| 亚洲欧美日韩国产四季一区二区三区 | 亚洲一区在线观看青青蜜臀| 亚洲午夜成人精品电影在线观看| 日本一区三区高清视频|