        How to drive fast becoming master? You need to know the definition of the inverter 15

        2023-05-20 11:28:43

        I believe a lot of power to drive practitioners are not familiar with, as opposed to conventional electrical circuit control, high technology content converter, it is a combination of strong and weak electrical equipment, so its failure varied, only constantly sum up experience combined with theoretical knowledge from practice, exemplified below 15 frequently asked questions about the frequency converter (inverter definitions and some failures often occur), which is something you know?


        1. What is the frequency resolution? What is the significance?


        For digital control drive, even when the frequency command is an analog signal, the output frequency is also given level. The smallest unit is called the differential frequency resolution. Frequency resolution is typically a value of 0.015 ~ 0.5Hz. For example, resolution is 0.5Hz, 23Hz then the above may become 23.5,24.0 Hz, so the operation of the motor is also a follower stage. For use as such a control winding on a continuous cause problems. In this case, if the resolution is about 0.015Hz, for the four motors of a differential 1r / min or less, can be sufficiently adapted. Further, some types of aircraft given the same resolution and the output resolution is not.


        2, there is acceleration time and deceleration time can be respectively given models, and ramp time together given the aircraft, what's the point?


        Deceleration may each given model, for quick acceleration, slow deceleration occasions, or for a small machine requires strict tact time given occasion is suitable, but for the fan drive and so on, have a longer deceleration time, acceleration and deceleration times can be given together.


        3. What is regenerative braking?


        If the motor operation command to reduce the frequency, the running state of the motor becomes an asynchronous generator, operates as a brake, which is called regeneration (electric) braking.


        4, would be given a greater braking force?


        Regeneration energy from the motor out of the filter capacitor storage drive, since the relationship between the capacity and voltage of the capacitor, the regenerative braking force general inverter rated torque of about 10% to 20%. As to optional brake member units, it can reach 50% to 100%.


        5, inverter protection?


        Protection can be divided into the following two categories:


        (1) for detecting automatically correcting operation after an abnormal state, such as stall prevention overcurrent, overvoltage stall prevention regeneration.


        (2) after detecting abnormal power semiconductor devices blocking the PWM control signal, the automatic stop of the motor. The overcurrent-cutoff, regenerative overvoltage cut, overheating and cooling fan semiconductor instantaneous power failure protection.


        6. Why continuous load clutch, the protection function of the inverter on the action?


        When the load is connected with the clutch, an abrupt change in an instant, the motor slip to a large area of the connection from the idling state, a large current flows through the inverter overcurrent trip cause, can not operate.


        7, in the same factory with moving large motors, inverter operation stops, why is this?


        Will flow through the motor when starting and the starting current corresponding to the volume, the stator side of the transformer generates a voltage drop of the motor, this drive is large drop on a large capacity motor, connected to the same transformer undervoltage or instantaneous stop will be made the judge, therefore sometimes protection (IPE) action, resulting in shutdown.


        8, stall prevention function is what does this mean?


        If a given acceleration time is too short, the inverter output frequency far exceeds the speed variation (electrical angle frequency), because the drive current flowing through the trip operation is stopped, which is called stall. In order to prevent stalling the motor continues to operate, it is necessary detected magnitude of current frequency control. When the acceleration current is too large due to slow the rate of acceleration. The same is true when decelerating. The two together is the stall function.


        9, when the installation of the inverter mounting orientation Is there a limit?


        Internal structure and the back of the drive considers the cooling effect, the relationship between the upper and lower ventilation is important, therefore, for a haplotype within the disc, are hung on the wall in longitudinal position, vertical as possible.


        10, inverter overvoltage


        Overvoltage alarm typically occur when the shutdown, mainly due to the deceleration time is too short or the braking resistance and unit in question.


        11, Drive over temperature


        Further there are drive temperature faults, such as high temperature alarm occurs, the temperature sensor is normal by inspection, it may be due to interference can be shielded fault, should also check the ventilation fan and the drive case. For other types of faults, preferably contact the manufacturer to obtain a quick viable solution.


        12, inverter over-current alarm is the most frequent phenomenon


        Inverter over-current phenomenon


        (1) restart, a liter of speed on the trip. This is very serious over-current phenomenon. The main reasons are: the short-circuit load, the mechanical parts are stuck; inverter module damage; motor torque is too small to cause such phenomena.


        (2) Power jump phenomenon typically can not be reset, for two main reasons: module bad, bad drive circuit, the current detection circuit bad. When the trip but does not immediately restarted at the time of acceleration, the main reasons are: acceleration time is too short, the current limit is set too small, high torque compensation (V / F) setting.


        Can 13, not soft start, the motor drive directly into a fixed frequency?


        At very low frequencies is possible, but only if the given frequency with a high frequency power directly starting similar. The starting current flowing (6-7 times the rated current), due to the over-current converter switches, the motor can not start.


        14, when the motor exceeds 60Hz operation noted that the problem?


        More than 60Hz operation should note the following


        (1) mechanical means and at the full speed operation may be (mechanical strength, noise, vibration, etc.)


        (2) the motor enters the constant power output range, the output torque can be maintained for a work (fans, pumps, etc. the shaft output increases proportional to the cube of the speed, it is also noted that the rotational speed rises slightly).


        (3) produce bearing life issues should be fully taken into account.


        15, do not drive long-term what will happen?


        1. The inverter fan bearing lubricant dry, affect the use.


        2. Long-term high-voltage filter capacitor bulge not easy, low-voltage electrolytic capacitors prone to leakage.


        專(zhuān)用變頻器


        label

        QR code

        The public,

        Mobile station
        The public, Mobile station

        Contact

        未標(biāo)題-8.png 0755-81719517
        未標(biāo)題-10.png0755-81719530 未標(biāo)題-11.pngamb@ambition.com.cn
        未標(biāo)題-12.pngFloor 1, 5 and 6, building 7, lijincheng science and technology industrial park, gongye dong road, longhua new district, shenzhen

        Navigation

        Home          About

        Product      Case

        Solution      Service

        Job      News

        Contact          

        Copyright © Shenzhen Ambition Electronic Co., Ltd Record number:備案號(hào):粵ICP備12045920號(hào)
        主站蜘蛛池模板: 精品国精品国自产在国产| 中文字日产幕码三区国产| 国产 另类 在线 欧美日韩| 香蕉乱码成人久久天堂爱| 国产乱沈阳女人高潮乱叫老| 天天看片视频免费观看| 狠狠色丁香婷婷综合尤物| 人人妻人人添人人爽日韩欧美| av天堂中av世界中文在线播放| 国产高清一区二区三区视频 | 九九热免费精品视频在线| 人妻在厨房被色诱中文字幕| 99精品国产综合久久久久五月天| 亚洲欧洲日产国无高清码图片 | 欧美黄网在线| 国产在线国偷精品产拍| 久久亚洲色www成人| 偷炮少妇宾馆半推半就激情| 又爽又黄又无遮挡的激情视频| 97视频精品全国免费观看| 欧美18videosex性欧美tube1080 | 18禁无遮挡啪啪无码网站| 欧美韩中文精品有码视频在线| 亚洲午夜福利在线观看| 日韩在线视频一区二区三区| 久久这里只精品热免费99| 亚洲顶级裸体av片| 亚洲精品国产av一区二区| 五月综合激情婷婷六月| 又爽又黄又无遮掩的免费视频| 爱豆传媒md0181在线观看| 成人午夜电影福利免费| 久久99精品久久久久久9| 日韩在线观看精品亚洲| 亚洲女同精品一区二区久久| 中文字幕在线精品国产| 亚洲精品二区在线播放| 国产精品美女一区二区三| 久久综合五月丁香久久激情| a级免费视频| 国产又黄又湿又刺激网站|