        The reason and debugging method of converter torque promotion

        2023-05-20 13:49:45

        1. Causes of torque increase


        It is important to set up the torque lifting function. The frequency converter is widely used in V / F control mode. When the power frequency of the motor decreases, the speed of the motor will also decrease. If the load torque remains unchanged, its output power will also decrease. According to the principle of energy conservation, if the torque of the load is constant, the current cannot be reduced. Only by reducing the voltage can the energy balance be maintained between the input and output. If the corresponding voltage of motor input is UX and the frequency drop is FX, then:


        ① Voltage regulation ratio Ku = UX / UN


        ② Frequency regulation ratio KF = FX / FN


        Where, UN and FN. They are rated voltage and rated frequency respectively. When Ku = KF, the voltage and frequency decrease in direct proportion. Since the speed of the motor is determined by frequency, the specific reflection of the decrease in the proportion of output power is the reduction of electromagnetic torque, which reduces the load capacity of the motor. If the load capacity of the motor is not reduced, when the voltage and frequency decrease at the same time, the voltage should be appropriately increased on the basis of Ku = KF to make Ku > KF. Since the purpose of increasing voltage is to increase torque, it is called torque improvement, also known as torque compensation. The amount of torque increase reflects the ratio of voltage to frequency. Debugging torque increase is actually to adjust U / F ratio


        2. U / F curve of torque increase


        Almost all inverter products provide dozens of U / F curves for users to choose. Due to the different models of products, their U / F curves are roughly linear, polygonal and arbitrary polygonal. It can be selected according to the load characteristics of the motor and the instructions of the inverter user manual.


        3. Influence of U / F ratio on load


        Torque increase is to compensate for the low speed torque reduction caused by the resistance of motor stator winding, and increase the low frequency range U / F. When the U / F ratio is too small, the motor is difficult to start or can be started but can not carry load at low frequency. If the U / F ratio is too large, the motor will not save energy in low frequency operation, and even the inverter will trip due to the high saturation of the magnetic circuit.


        The above mentioned is only a basic influence situation, which should be considered, set and adjusted according to the characteristics of the load carried by the motor on site. For constant torque load with wide speed range, such as belt conveyor, it is necessary to consider whether the dynamic load can be carried in low frequency operation when setting, and the U / F should be set larger. For light load startup and heavy load operation objects, the torque can not be increased or increased less; for fan and pump load, the curve with weak reduction characteristics should be selected at low frequency. Frequency converters are designed with "automatic" for torque lifting. If it is set to automatic, the voltage during acceleration can be automatically increased to compensate the starting torque, so that the motor can be accelerated smoothly. For novices with insufficient debugging experience or unclear load characteristics, it is a good choice to use "automatic". If manual compensation is used, the better curve can be selected according to the load characteristics, especially the starting characteristics of the load. For variable torque load, if it is not selected properly, the output voltage at low speed will be too high, which will waste electric energy. Even when the motor starts with load, the current will be large and the speed will not go up.


        General purpose frequency converter


        label

        QR code

        The public,

        Mobile station
        The public, Mobile station

        Contact

        未標題-8.png 0755-81719517
        未標題-10.png0755-81719530 未標題-11.pngamb@ambition.com.cn
        未標題-12.pngFloor 1, 5 and 6, building 7, lijincheng science and technology industrial park, gongye dong road, longhua new district, shenzhen

        Navigation

        Home          About

        Product      Case

        Solution      Service

        Job      News

        Contact          

        Copyright © Shenzhen Ambition Electronic Co., Ltd Record number:備案號:粵ICP備12045920號
        主站蜘蛛池模板: 国产精品小视频一区二页| 亚洲精品日韩在线丰满| 中国帅小伙gaysextubevideo| 亚洲高清在线天堂精品| 日韩中文字幕亚洲精品 | 久爱www人成免费网站| 亚洲线精品一区二区三八戒| 国产精品免费中文字幕| 国产精品久久久久久久久久免费| 国产激情精品一区二区三区| 无码人妻一区二区三区在线视频| 中文字幕无码视频手机免费看| 成人3D动漫一区二区三区| 综合久久夜夜中文字幕| 无码精品一区二区免费AV| 无码中文av波多野结衣一区| 亚洲欧洲av一区二区久久| 国产福利在线观看免费第一福利| 国产91在线播放免费| 亚洲精品一品二品av| 激情在线网| 人妻在线无码一区二区三区| 国产AV福利第一精品| 干老熟女干老穴干老女人| 国产精选一区二区三区| 无码国产精品免费看| 免费人成视频网站在线18| 俄罗斯性孕妇孕交| 国产粉嫩一区二区三区av| 无码熟妇人妻av在线电影| 国产乱码日产乱码精品精| aa级毛片毛片免费观看久| 99久久99久久久精品久久| 亚洲国产高清第一第二区| 亚洲精品天堂在线观看| 亚洲av成人无码精品电影在线| 亚洲色欲色欲WWW在线丝| 免费a级黄毛片| 亚洲AV无码一区二区三区在线播放| 亚洲国产精品一二三四区| 国产一级在线观看www色|