        Matters needing attention when PLC and frequency converter cooperate

        2023-05-20 13:04:21

        In the current production conditions, when using frequency converter to form an automatic control system for control, in many cases, it is necessary to use PLC and frequency converter to match, such as bearing cleaning, packaging paper printing, PCB production, etc.


        PLC can provide on-off signals of various control signals and instructions through output point or communication. The following introduces the matters needing attention when the inverter and PLC cooperate.


        1. Input of switch command signal


        The input signal of frequency converter includes the switch type command signal to control the operation states such as operation / stop, forward / reverse rotation, segment speed and inching. Frequency converter usually uses relay contact or components (such as transistors) with relay contact switch characteristics to connect with PLC to obtain operation status instructions.


        When using relay contacts, misoperation is often caused by poor contact; when connecting with transistors, the voltage and current capacity of transistors should be considered to ensure the reliability of the system.


        When designing the input signal circuit of frequency converter, attention should be paid to that when the input signal circuit is not connected properly, it will also cause the malfunction of the frequency converter. For example, when the input signal circuit uses the inductive load such as relay, the surge current generated by the relay opening and closing may cause damage or failure of the internal components of the frequency converter, and then cause the frequency converter to malfunction. Therefore, this situation should be avoided as far as possible.


        When the input switch signal enters the frequency converter, the crosstalk between the external power supply and the converter control power supply (DC24 V) sometimes occurs. The correct connection is to use PLC power supply to connect the collector of external transistor to PLC through diode.


        2. Input of numerical signal


        There are also some numerical command signals (such as frequency, voltage, etc.) in the inverter, which can be divided into analog input and analog output. The analog input is given from outside through the terminal, usually through the voltage signal of 0-10V / 5V or the current signal of 0 / 4-20mA. Because the interface circuit varies with the input signal, the output module of PLC must be selected according to the input impedance of frequency converter.


        When the voltage signal range of frequency converter and PLC is different, such as the input signal of frequency converter is 0 ~ 10V, while the output voltage signal range of PLC is 0 ~ 5V; or when the output signal voltage range of PLC side is 0 ~ 10V and the input voltage signal range of inverter is 0 ~ 5V, due to the limitation of allowable voltage and current of frequency converter and transistor, parallel and series connection mode is needed The resistance is connected to limit the current or part of the voltage to ensure that the corresponding capacity of PLC and inverter is not exceeded when opening and closing. In addition, attention should be paid to separate the control circuit from the main circuit when connecting the wire. It is better to use shielded wire to ensure that the noise on one side of the main circuit will not be transmitted to the control circuit.


        Note: the input impedance of PLC side should ensure that the voltage and current in the circuit do not exceed the allowable value of the circuit, so as to ensure the reliability of the system and reduce the error.


        In addition, when using PLC for sequence control, due to the time required for data processing, the different order of programming and the different use of instructions, there will be a certain time delay in the operation of the system, so the above factors should be considered in more accurate control.


        Because the inverter will produce strong electromagnetic interference in the operation, in order to ensure that PLC will not be fault because of the noise generated by the main circuit breaker and switching devices of the inverter.


        Therefore, the following points should be paid attention to when the inverter is connected with PLC:


        (1) PLC itself should be grounded according to the specified wiring standards and grounding conditions, and attention should be paid to avoid using common ground wire with frequency converter, and the two should be separated as far as possible during grounding.


        (2) When the power supply condition is not good, noise filter, reactor and devices that can reduce noise should be connected to the power line of PLC power module and I / O module. In addition, if necessary, corresponding measures should be taken at the input side of frequency converter.


        (3) When the frequency converter and PLC are installed in the same operation cabinet, the wires related to frequency converter and PLC shall be separated as far as possible.


        (4) Through the use of shielded wire and twisted pair to improve the level of noise interference.


        Shenzhen frequency converter


        label

        QR code

        The public,

        Mobile station
        The public, Mobile station

        Contact

        未標題-8.png 0755-81719517
        未標題-10.png0755-81719530 未標題-11.pngamb@ambition.com.cn
        未標題-12.pngFloor 1, 5 and 6, building 7, lijincheng science and technology industrial park, gongye dong road, longhua new district, shenzhen

        Navigation

        Home          About

        Product      Case

        Solution      Service

        Job      News

        Contact          

        Copyright © Shenzhen Ambition Electronic Co., Ltd Record number:備案號:粵ICP備12045920號
        主站蜘蛛池模板: 国产精品无码无片在线观看3d| 亚洲成人午夜排名成人午夜| 免费无码又爽又刺激高潮的app| 免费人成在线观看成人片| 少妇人妻呻呤| 久久精品国产亚洲综合av | 给我播放片在线观看| 亚洲精品久久无码av片软件| 97人妻蜜臀中文字幕| 国产精品分类视频分类一区| 小嫩批日出水无码视频免费| a级毛片在线免费观看| 在线a亚洲老鸭窝天堂| 妺妺窝人体色www看人体| 日韩av一区二区不卡在线| 乱女乱妇熟女熟妇综合网| 亚洲国产精品日韩av专区| 午夜在线不卡| 午夜福利92国语| 国产精品国语对白露脸在线播放 | 亚洲精品久久7777777国产| 久久青青草原亚洲AV无码麻豆| 欧美大胆老熟妇乱子伦视频| 日韩成人一区二区二十六区| 免费人成网站免费看视频| 国产va免费精品高清在线| 亚洲精品熟女一区二区| 国产人妖cd在线看网站| 国产一区精品在线免费看| 337P日本欧洲亚洲大胆在线| 国产偷国产偷亚洲高清人| 欧美成人精品三级网站视频| 亚洲在战av极品无码| 亚洲一区无码精品色| 免费国产拍久久受拍久久| 国产愉拍91九色国产愉拍| 国产精品乱码久久久久久小说| 韩国无码AV片在线观看网站| 亚洲精品中文字幕日本| 永久免费无码成人网站| 亚洲国模精品一区二区|